When possible, vertical wells are separated by 15 feet to
avoid thermal interference between wells. The closed-loop
heat exchanger is constructed from two parallel lengths of
0.75-inch polyethylene pipe, and a "U" bend is welded to
the bottom end to connect the supply and return side of the
exchanger. Once the exchanger is assembled, it is
pressure-tested and a ten-foot section of re-bar is taped
to it to keep the lead section straight. Next, a grout line
is loosely attached and the exchanger is filled with water
to prevent it from floating back out of the well if the
well begins to fill with water. Once inserted into the
well, the bore is grouted up with a bentonite clay slurry
and the grout pipe is removed for reuse on the next well.
The bentonite grout serves two functions: to seal the well
and prevent contamination from surface sources, and to
provide a medium for heat transfer between the exchanger
tubing and the side wall of the well bore.